Description

Quick-loading alcohol base oil and oil linkage frying stove controller function description

The controller is a moisture-proof structure of the whole plastic case, and has its own lead-out line. It is used for electric heating and alcohol-free atomizing stove without fan. In addition to the functions of conventional fan, ignition output, electromagnetic pump gear output, etc., there are also 5 files. The key oil and oil linkage makes the matching of the air volume and the oil volume of each gear in the best, and the fast 5 gear and the rocker switch realize the effect of no need to switch, fire and heart, and control freely. There are also models with infrared anti-air burning to choose from, easy to achieve considerable energy savings.

The controller is quick and easy to install, stable, adaptable and user-friendly, and cost-effective. It is a replacement for the alcohol-based fuel atomizer industry. Basic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V

3, the service life: the number of actions is not less than 100,000 times

4, fan power: no more than 200W, full power range PWM voltage regulation

5, ignition output: AC220V, power is not more than 100W

6, electromagnetic pump output: AC220V, power is not more than 100W, full power range PWM voltage regulation

8, personality function: external one-word rocker switch or three-speed self-reset switch need to buy Infrared air defense function optional Wiring instructions

1. Brown-blue black sheathed wire: Connected to 220V AC power supply, the leakage circuit breaker and a bipolar switch should be installed at the front end of the power supply to play the role of reliable control of the total power supply and safety protection.

2, brown-blue black sheathed cable with cold-pressed flat connector: plug-in fan, its output voltage is adjustable AC voltage, because of the unique micro-computer controlled high anti-interference non-contact PWM full power The adjustment technology can obtain stable output even when the igniter is ignited, no malfunction occurs, and the air volume control output is stable.

3. Brown-blue black sheathed wire with cold-pressed round connector: Plug-in electromagnetic pump, its output voltage is adjustable AC voltage, due to the unique micro-computer controlled high anti-interference non-contact PWM The power adjustment technology can obtain stable output even when the igniter is ignited, and there is no malfunction. Matching with commonly used imported electromagnetic pumps allows the electromagnetic pump to perform optimally.

4. Black sheathed cable with black combination connector: plug the 220V igniter.

5. Three-core black sheathed wire with split lug: Connect one-way two-way rocker switch or three-speed self-reset switch. The switch with the branch line is on the same side, and the other line with no branch is connected to the other side of the switch.

6. There are two black sheathed wires with waterproof joints, which are connected to the infrared emitting head and the receiving head with glass window. The receiving head is a four-core cable, which is connected by the attached special extension cable. The receiving head on the back panel. Setting instructions

The following instructions are all performed when the controller's settings are in the factory state and the controller is powered on. Whether other interfaces are connected or not connected does not affect the setting operation.

After the controller is powered on, all the digital tubes and LED indicators will be lighted up. You can use this opportunity to check whether there are any missing or missing lights. Finally, the digital tube displays OFF, which is the shutdown state.

Press the start/stop button in the off state, the system enters the working state and starts according to the default starting gear position. The current position of the digital tube.

1. Modify the electromagnetic pump and air volume output power parameters: press and hold the setting button for about 5 seconds, the red digital tube displays d-1, indicating that the first power output parameter setting menu is entered, and then press the setting button, the green digital tube displays the gear position. At present, the percentage of output power, at this time press the increase and decrease buttons, the power output parameters can be adjusted between 0-100.

★ Parameter confirmation save: adjust the parameters, press and hold the setting button, the number starts to flash until the red display SAU, indicating that the parameter is saved successfully, and the system exits the setting state.

★ After adjusting the first gear parameters, if you need to adjust other gear parameters, you can press the setup button again to return to display d-1, and the data is temporarily stored. Press the increase and decrease button to enter F-1, d-2, F-2, d-3, F-3, d-4, F-4, d-5, F-5 and other gears in turn. Set the parameters of each file as described above, and finally press and hold the setting button until the SAU is displayed, and all the parameters before saving are completed at one time.

★If the above operation does not long press the setting button and display SAU, the new parameters will not be officially saved. If there is no operation for a few seconds or the system is started by pressing the start/stop button, the system will still run according to the original parameters. ★ default values ​​of each file: D-1: 30; F-1: 30; D-2: 35; F-2: 35; D-3: 40; F-3: 40; D-4: 45; F-4: 45; D-5: 50. F-5: 50.

2, modify the underlying parameters: display d-5 and then press the minus button, the digital tube shows FoN to enter the underlying parameter settings menu, and then press the minus button to display FoF, odH, oPP, dLb, boF, dEF, oNS, oNF and other menus .

1 The FoN menu is the front cleaning option; the default value is 0; the setting range is 0-20 seconds. ★ Parameter meaning: Clean before starting.

2 The FoF menu is the post-cleaning option; the default value is 0; the setting range is 0-20 seconds.

★Parameter meaning: Clean after turning off the fire.

3 The odH menu is the continuous ignition time option; the default value is 12; the setting range is 1-20 seconds.

The meaning of the parameter is: After the electromagnetic pump is working, the ignition output will stop after the corresponding time.

4 The oPP menu is the boot gear option; the default value is 2; the setting range is 0-5.

The meaning of the parameter is: the output power gear value of the electromagnetic pump when the start button is pressed.

5 The dLb menu is a delayed pump option; default: 0; setting range: 0-30 seconds.

The meaning of the parameter is: the electromagnetic pump is started when the delay is delayed after the ignition.

6 boF menu anti-air burning no pan off fire small air volume size options; default value: 35; setting range: 0-100.

The meaning of the parameter is: the percentage of the output power of the small air volume when the air defense is not fired.

7 The dEF menu is the downshift air volume rapid deceleration rate option; default value: 0; setting range: 0-50.

The meaning of the parameter is: when the large gear is reduced to the small gear, the wind turbine will slow down rapidly.

8 The oNS menu is an effective option for the anti-air-burn function; default value: 0; setting range: 0-1.

The meaning of the parameter is: 1 means enabled. 0 means deactivated, anti-air burn function is invalid.

9 The oNF menu is to enable the small air volume option when the air defense is burned off; the default value is 0; the setting range is 0-1.

The meaning of the parameter is: 1 means enabled. 0 means deactivated.

3, restore the factory settings: the controller is powered off, press and hold the minus button at the same time to turn on the power, display the rEc release button, long press the set button until the display SAU means that the factory settings are successful, all the parameters can be set at this time Both returned to the factory state.