Additional information
Origin | Mainland China |
---|---|
Feature | Stocked |
Model Number | DQ3 |
Material | Plastic |
Type | Kitchen Lighters |
Certification | CE / EU |
73.75 $
68 in stock
Origin | Mainland China |
---|---|
Feature | Stocked |
Model Number | DQ3 |
Material | Plastic |
Type | Kitchen Lighters |
Certification | CE / EU |
1, product model: DQ3. 2, the main function: delay super ignition. 3, working voltage range: AC175V-245. 4, the service life: ≥ 100,000 times.
5, ignition intensity: super ignition, can ignite flammable gas and various alcohol-based biofuels. The igniter can also ignite alcohol-based fuel when the ignition needle is wet, so it is especially suitable for igniting alcohol-based fuel. 6, ignition high pressure: ≥ 15Kv.
7, delay to stop the ignition time: turn on the AC 220V power supply, automatically stop the ignition after 12 seconds of ignition, time delay ignition can be determined according to customer requirements
8, the whole epoxy resin is potted, waterproof and moisture proof, and the igniter shell is made of high temperature flame retardant material.
Second, commercial stove super igniter – DQ3 ignition high voltage line connection instructions
Two high-voltage ignition wires 800mm of the igniter are connected to the double-pin ignition needle for relative ignition, or one high-voltage ignition wire 800mm is connected to the ignition needle, and the other high-voltage ignition wire 800mm is connected to the furnace body, the ignition pin and the burner metal. The distance between the two is 5-6mm, and the ignition is discharged for the burner to form an ignition circuit. Ignition high-voltage line connection: The company strongly recommends that the customer use the dual-purpose ignition for the ignition needle. This kind of ignition effect is better. If the double-needle can only be used with a single needle because of the burner, one of the high-voltage output leads 800mm Connect the ceramic ignition needle, another high-voltage output lead 800mm must be fixed on the burner with screws. The distance between the ignition needle and the metal of the burner is 5-6mm. The ignition is discharged against the burner to form an ignition circuit. Note that it is not on the stove, it is not attached to the hob. If it is connected to the hob, the ignition circuit is very long. Moreover, the hob and the burner are not necessarily connected, so the ignition is cut off. In the loop, the igniter only uses half the power. Maybe you can hardly understand the truth at the same time. Maybe you will say that I have been connected in this way. It is very good. You just have to try it. So the igniter output high voltage line produced by our company is double long line. For a length of 800mm, refer to the igniter connection diagram below.
Third, the commercial stove igniter – DQ3 working process
1. Turn on the 220V power switch and enter the standby state.
2. Start the jog button switch and ignite the ignition. At this time, the burner gas valve can be turned on to ignite the combustible gas or alcohol-based fuel, and the ignition is automatically stopped after 12 seconds of ignition. Enter normal combustion.
3. If you want to stop the stove work, first close the air valve, then turn off the 220V power switch.
Fourth, high frequency high energy igniter installation precautions
1. The installer must have an electrician installation qualification.
2. 2. The rated input voltage of this igniter is 220V 50HZ. A qualified leakage circuit breaker must be installed at the front end of the power supply. The metal casing of the cooker must be protected by a grounding wire. It is strictly forbidden to connect the metal casing with a neutral wire!
3. The control switch on the panel should use a bipolar power switch of not less than 5A/250V, and the igniter power cord is connected to the power switch.
4. 4. The igniter can be fixed or suspended in the lower space of the cooker, and high temperature radiation baking should be avoided.
5, 5. High-voltage line is connected to the ignition needle. It is recommended to use dual-ignition ignition mode. The discharge spacing of the ignition needle is 3-5mm. Try not to use the single-discharge method. If only one high-voltage line is connected to the ignition needle, the other high-voltage line must be reliably connected. On the metal body of the burner, it can not be easily connected to the metal casing of the cooker, which will bring many difficult problems!
6. 6. The length of the high-voltage line is “long enough and shortest”. It is better to separate the two lines by more than 3 cm, and keep a certain degree of drooping arc to facilitate the oil drop. The high-voltage line can not be extended continuously. The wiring is not allowed to be close to the iron frame and iron plate of the stove. Do not add all kinds of casings. Never use the two high-voltage wires to twist together to avoid high-frequency high-voltage leakage!
7. Regularly clean up debris and do not rinse with water.
Five, the main product type of commercial stove igniter
The commercial stove igniter series products produced by our company are divided into powerful igniter, super igniter and high-energy igniter according to the ignition intensity. There are two kinds of delay ignition and continuous ignition according to the ignition mode. Electric start, jog button start and switch start, as well as output control fan start, so the following series of products have been produced, customers can purchase according to needs, or customize products according to customer requirements.
1; Strong ignition: This type of igniter is suitable for igniting flammable gas or vaporized alcohol-based fuel, and can also ignite high-purity liquid alcohol-based fuel.
2; super ignition: This type of igniter can ignite flammable gas and alcohol-based fuel, and the ignition needle can be ignited with a little water. It is especially suitable for point-based alcohol-based fuels, which contain different proportions of water in alcohol-based fuels.
3; high-energy ignition: This type of igniter has the strongest ignition capacity. The spark is like a flame. It can ignite some difficult fuels. It is also suitable for large-scale cooking stoves with fans. Because of the fan, the ignition sparks are scattered. Increasing the ignition area makes it easier to catch fire. Customers can choose according to their needs.
The commercial stove igniter produced by our company mainly has the following functions:
1, continuous ignition; ignition after powering until the power is turned off,
2, delay ignition; ignition after ignition for a certain time will automatically stop ignition, a certain time is generally 10-12 seconds, can also be set according to customer needs. If some customers require a delay ignition time of 20 seconds. The advantage of using such an igniter is that the life of the igniter is greatly extended.
3. The low-voltage jog button switch is activated; the igniter has a set of low-voltage switch start leads connected to the low-pressure push button switch to realize the low-voltage start igniter. This ignition mode is safer, not afraid of leakage and electric shock, and the low-voltage switch starts a little moving and button Self-locking, this is based on the user's habits.
4, synchronous control of the fan; igniter has a set of 220V voltage output leads, can be used to control the fan or electromagnetic pump.
The above functions can be selected according to their own needs. If there are other functions to be implemented, they can be customized.
The main products of the igniter produced by the company are as follows. 1, DQ7: 220V continuous powerful ignition. 2, DQ2: 220V with extended powerful ignition. 3, DQ6: 220V continuous super ignition. 4, DQ3: 220V with time delay super ignition.
5, DQ5: 220V with time delay super ignition, low pressure button start.
6, DQ8: 220V with time delay super ignition, low pressure button start, synchronous control fan or electromagnetic pump. 7, DY3: 220V continuous high-energy ignition. 8, DY1: 220V with delayed high-energy ignition.
9, DY2: 220V with delayed high-energy ignition, low-voltage button to start.
10, DY6: 220V with delayed high-energy ignition, low-pressure button start, synchronous control of the fan or electromagnetic pump.
Gas Infrared Burner Igniter: Widely used in the ignition of industrial equipment gas burners in the fields of pre-coating treatment, drying and solidification, food baking, agricultural product drying, glass manufacturing, indoor and outdoor heating, paper making, printing and dyeing, etc. Control System. Gas igniter features: gas igniter, programmatic integrated IC control; two relays, to ensure the automatic adjustment of the circuit, safety protection, weak control, conversion circuit, etc.; high-quality insulation potting plastic packaging, more enhanced Security. The output high voltage is 16KV. In normal use, the flameout can be automatically re-ignited. When the timeout is 20 seconds, the gas solenoid [...]
77.49 $ Add to cartFunctional Overview BF-15B + microcomputer temperature difference controller, directly set the temperature difference upper limit to achieve the effect of temperature control of the water cycle, the panel is simple and convenient to operate. To make hot and cold water cycle, mainly by improving the thermal efficiency high and low temperature difference between the value measured by the sensor and the upper and lower limit set temperature difference. Mainly used in hot water circulation system backwater control. The main function Function Name Function Description Temperature control when the temperature difference T ≤T limit, normally open relay disconnected, normally closed pull; [...]
82.00 $ Add to cartFirst, the methanol no fan electric furnace head intelligent controller detailed description The controller is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition, electromagnetic pump speed regulation, etc., it can also expand external precision regulator to achieve precise adjustment of oil pump flow and Start-stop control, this function and gear position adjustment achieve the effect of no need to switch, fire with heart, start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear [...]
92.50 $ Add to cartHW-103 igniter: also known as industrial furnace pulse ignition controller, this product is mainly used for ignition and control of various industrial equipment and hotel stoves using liquefied gas, natural gas, artificial gas. Power-on ignition or switch-controlled ignition accidental flameout key ignition function, ion flame automatic monitoring function and flameout alarm, ignition failure and accidental flameout automatically cut off gas source safety protection, using microcomputer digital control technology, using lightning protection technology Power-on ignition/switch Control the ignition, stop the ignition after the flame is automatically detected, the solenoid valve keeps the combustion indicator light on, and when the ignition time [...]
92.50 $ Add to cartBasic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V 3, the service life: the number of actions is not less than 100,000 times 4, fan power: no more than 600W 5, ignition output: AC220V, power is not more than 100W 6, electromagnetic pump / valve output: AC220V, power is not more than 100W 7, circulating water pump output: AC220V, power is not more than 1000W Wiring instructions 1. Brown-blue black sheathed wire: Connected to 220V AC power supply, the leakage circuit breaker and a bipolar switch should be installed at the front end of the power [...]
140.00 $ Add to cartN series atomization controller description This series of controllers is used in conjunction with a methanol spray burner for ignition and fire regulation. With the extinguishing function, it can be used in places such as steaming furnaces. System parameter setting method: Press and hold the setting button to enter the system parameter setting, turn the knob to select the desired menu, press the setting button to display the value, turn the knob to adjust the value, and then press and hold the setting button until the SAU is displayed, indicating that the saving is successful. Note: If you do not [...]
177.50 $ Add to cartF2 type with fine adjustment anti-air burning commercial stove controller description The controller is suitable for the alcohol oil electromagnetic pump injection combustion system with blower, has infrared automatic air defense burning function, external igniter, can realize automatic high energy ignition and air defense burning, can meet the automatic control and safety energy saving needs of modern kitchen stoves. . Basic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V 3, the service life: the number of actions is not less than 100,000 times 4, fan power: no more than 300W 5, igniter power: AC220V, no more [...]
208.75 $ Add to cartPortable Electric Arc Lighter USB Rechargeable Windproof Electronic Lighter Eco-friendly Aromatherapy for Candles Gas Stoves Feature: 1.Windproof and Flameless Technology: The Arc lighter adopt windproof design and flameless plasma technology to protect the electric pulse from being blown out by strong wind or wet weather. 2.Safty Protection: Its so much easier to light candles with this than traditional butane lighters or matches. A safety lock design keeps children away from fire. The long and flexible soft head allows you to keep a safe distance from sparks. 3.USB Charging: The lighter uses a [...]
Commercial stove infrared anti-air burning controller function description The controller is a commercial stove controller without fan control the fan can be independently controlled, which can realize automatic high-energy ignition and anti-air burning, and meet the needs of automatic control and safety protection of modern kitchen stoves. Controller working process: The controller turns on the power switch, starts ignition, opens the oil valve, and after 12 seconds, the ignition stops and enters the combustion state. At this time, the infrared sensor head and the receiving head constitute a pot sensor to detect whether there is a pot on the furnace, [...]
177.50 $ Add to cartY2 commercial gas stove flameout safety protection ignition controller function description The controller is used on commercial stoves to realize automatic high-energy ignition and accidental flameout protection to meet the automatic control and safety protection of modern kitchen stoves. First, Y2 commercial stove flameout safety protection controller basic parameters 1, product model: Y2. 2, working voltage range: AC175-245V 3, service life: ≥100,000 times 4, ignition intensity: high-energy ignition, can easily ignite combustible gases and various alcohol-based biofuels. 5, there is an accidental flameout safety protection function, when the accidental flameout, the solenoid valve is closed and an alarm sounds. 6, [...]
158.75 $ Add to cartN series atomization controller description This series of controllers is used in conjunction with a methanol spray burner for ignition and fire regulation. With the extinguishing function, it can be used in places such as steaming furnaces. System parameter setting method: Press and hold the setting button to enter the system parameter setting, turn the knob to select the desired menu, press the setting button to display the value, turn the knob to adjust the value, and then press and hold the setting button until the SAU is displayed, indicating that the saving is successful. Note: If you do not [...]
177.50 $ Add to cartInfrared beam debugging: a. The receiving head with a glass window at the side end of the aluminum infrared component has a built-in infrared receiving element and a status indicator. The light is always on to indicate that the correct infrared signal is received, indicating that the infrared light is not blocked, and the direction of emission and reception is basic Normal, in the effective range. On the contrary, the flashing light indicates that no infrared signal is received, indicating that the infrared light is blocked or emitted by the pot, and the receiving direction is not within the effective [...]
83.75 $ Add to cartFirst, the methanol no fan electric furnace head intelligent controller detailed description The controller is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition, electromagnetic pump speed regulation, etc., it can also expand external precision regulator to achieve precise adjustment of oil pump flow and Start-stop control, this function and gear position adjustment achieve the effect of no need to switch, fire with heart, start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear [...]
96.25 $ Add to cartChcę coś kupić ale szukam informacji jak zamówić... |
Kupiłem coś ale chcę poznać status zamówienia... |
Odebrałem paczkę ale mam pytanie lub problem... |
Chcę dokonać zwrotu i potrzebuję informacji... |
Droptech Sp. z o.o. droptech.polska@gmail.com |
ul. Łódzka 118, Piotrków Tryb. Sprzedajemy tylko przez internet |
NIP: 7712911090 REGON 386758083 |
Wysyłka bezpośrednio od producenta lub dostawcy |
DARMOWA WYSYŁKA + ubezpiecznie dostawy + śledzenie przesyłki |
CAŁKOWITY ZWROT podczas reklamacji |
Reviews
There are no reviews yet.