Hotel commercial gas stove flameout safety protection ignition controller

158.75 $

50 in stock

Additional information

Origin

Mainland China

Feature

Stocked

Model Number

Y2 commercial gas stove flameout safety protection ignition controller

Material

Plastic

Plastic Type

Melamine

Type

Kitchen Lighters

Certification

CE / EU

Description

Y2 commercial gas stove flameout safety protection ignition controller function description

The controller is used on commercial stoves to realize automatic high-energy ignition and accidental flameout protection to meet the automatic control and safety protection of modern kitchen stoves.

First, Y2 commercial stove flameout safety protection controller basic parameters 1, product model: Y2. 2, working voltage range: AC175-245V 3, service life: ≥100,000 times

4, ignition intensity: high-energy ignition, can easily ignite combustible gases and various alcohol-based biofuels.

5, there is an accidental flameout safety protection function, when the accidental flameout, the solenoid valve is closed and an alarm sounds.

6, the whole epoxy resin is potted, waterproof and moisture-proof, and the igniter shell is made of high-temperature flame retardant material.

Second, Y2 commercial stove flameout safety protection controller related connection: 1. The power cable is connected to 220V AC power.

2. Two ignition high-voltage lines are connected with double-needle with line ignition needle for relative ignition, or one ignition high-voltage line is connected to the ignition needle and another ignition high-voltage line is connected to the burner. The ignition forms an ignition circuit for the ignition of the burner, and the inspection fire line is connected to the fire detector for the flame. Detection.

3. The start line is connected to a non-self-locking button press and hold, release, not locked to start or stop working.

4. One solenoid valve line is connected to a 24V gas solenoid valve. 5. The ground wire is connected to the hob.

Third, Y2 commercial stove flameout safety protection controller working process:

1. The controller is powered on, the system enters the standby state, and waits for startup at any time.

2. Press the “Start and Stop Button”, the system “嘀” will start, the controller will start to ignite, open the air valve, ignite the fire, and after the fire detector detects the flame, open the main fire solenoid valve to ignite the main fire and enter the normal combustion state. Monitor the flame at any time. Once the accidental flameout occurs, the fire detector will not detect the flame, and the ignition controller will ignite again. If the fire needle is still not detected during the ignition, the ignition controller will immediately close the two solenoid valves and issue an alarm. sound.

3. Press “Start and Stop Button” during normal operation to stop working, close the valve and return to standby. Alarm sound meaning:

1. A periodic sound: pseudo-fire failure. That is, when there is a fire signal detected at the start, the solenoid valve has not been opened yet, and there should be no flame. At this time, there is a pseudo-fire fault, and it is necessary to check whether there is a problem with the fire line and the fire needle.

2. Two beeps periodically: Ignition failed fault. Ignition failed for 8 seconds without ignition. At this time, check whether the ignition pin discharge is normal, the solenoid valve is open, and the gas is interrupted.

3. Three rings periodically: Unexpected flameout failure. That is, the flame is unexpectedly extinguished during normal operation. In this case, check if the gas is interrupted. Shut down or exit the alarm:

During normal operation or fault alarm, if you press the “start and stop button” again, the work or alarm will be ended, that is, the valve will be closed, the buzzer will be turned off, and the standby state will be returned.

Commercial stove high energy igniter ignition effect diagram

Fourth, the commercial stove high energy igniter lead wire connection description

The company strongly recommends that the customer use the dual ignition for the ignition needle. This kind of ignition effect is better. If the double needle can only be used with a single needle because of the burner, one of the high voltage output leads 800mm is connected to the ceramic ignition needle. Another high-voltage output lead 800mm must be fixed on the burner with screws. The distance between the ignition needle and the metal of the burner is 5-6mm. The ignition is discharged against the burner to form an ignition circuit. Note that it is not on the stove, it is not attached to the hob. If it is connected to the hob, the ignition circuit is very long. Moreover, the hob and the burner are not necessarily connected, so the ignition is cut off. In the loop, the igniter only uses half the power. Maybe you can hardly understand the truth at the same time. Maybe you will say that I have been connected in this way. It is very good. You can understand it as soon as you try it. Therefore, the output voltage of the ignition controller produced by our company is double long line. For a length of 800mm, refer to the igniter connection diagram below. Also, the ground connection on the controller is also very important, and it is required to be firmly grounded. This way the controller is more resistant to interference. IMG_4181_copy

5. The company currently has the following types of commercial stove extinguishing controllers, which customers can choose according to requirements or require customization.

1; Y1-extinguish safety protection ignition controller: control a 24V gas double valve solenoid valve, this stove must have a long open flame, one of which controls the long open flame, the other is to control the main fire, the controller monitors the flame of the long open flame, If the flame is unexpectedly turned off, the solenoid valve is turned off to sound an alarm, and the fan is controlled synchronously. Before the ignition, the furnace is cleaned to prevent deflagration, and the cleaning time is 4 seconds.

2; Y2-extinguish safety protection ignition controller: control a 24V gas solenoid valve.

3; Y3-extinguishing safety protection controller: control a 24V gas double valve solenoid valve, this stove must have a long open flame, one of which controls the long open flame, the other is to control the main fire, the controller monitors the flame of the long open flame, such as In case of accidental flameout, the solenoid valve is closed and an alarm sounds.

4; Q1B-extinguish safety protection controller: control a 24V gas solenoid valve, synchronously control and monitor the fan, clean the furnace before ignition to prevent deflagration, cleaning time is 4 seconds