Gas commercial stove igniter, electronic vaporizer igniter, high pressure igniter

67.50 $

46 in stock

Additional information

Origin

Mainland China

Feature

Stocked

Model Number

DQ7

Material

Plastic

Type

Kitchen Lighters

Certification

CE / EU

Description

1, working voltage: AC220V 2, working voltage range: AC175-245V 3, service life: ≥100,000 times

4, ignition intensity: high-pressure powerful ignition, can ignite flammable gas and vaporized alcohol-based biofuels,

5, the igniter is sealed with epoxy resin, waterproof and moisture-proof.

6, ignition time: power on long ignition, continuous ignition.

Second, the commercial stove igniter – DQ7 lead wire plug connection instructions

1. Two high-voltage ignition wires 800mm are connected to the double-pin ignition needle for relative ignition, or one high-voltage ignition wire 800mm is connected to the ignition needle, and the other high-voltage ignition wire 800mm is connected to the furnace body, the ignition pin and the burner metal. The distance between the two is 5-6mm, and the ignition is discharged for the burner to form an ignition circuit. Ignition high-voltage line connection: The company strongly recommends that the customer use the dual-purpose ignition for the ignition needle. This kind of ignition effect is better. If the double-needle can only be used with a single needle because of the burner, one of the high-voltage output leads 800mm Connect the ceramic ignition needle, another high-voltage output lead 800mm must be fixed on the burner with screws. The distance between the ignition needle and the metal of the burner is 5-6mm. The ignition is discharged against the burner to form an ignition circuit. Note that it is not on the stove, it is not attached to the hob. If it is connected to the hob, the ignition circuit is very long. Moreover, the hob and the burner are not necessarily connected, so the ignition is cut off. In the loop, the igniter only uses half the power. Maybe you can hardly understand the truth at the same time. Maybe you will say that I have been connected in this way. It is very good. You just have to try it. So the igniter output high voltage line produced by our company is double long line. For a length of 800mm, refer to the igniter connection diagram below.

2, the input red high temperature line 500mm connected to 220V mains.

3, in order to facilitate the installation, you can customize the length of the cable plug and the connection terminal according to customer needs. High-voltage line terminal block as shown

Third, commercial stove igniter – DQ7 working process

1. Turn on the 220V power switch and ignite the ignition. At this time, turn on the gas valve of the stove to ignite the combustible gas or alcohol-based fuel and enter the normal combustion state. At this time, the igniter is continuously ignited.

2. If you want to stop the stove work, first close the air valve, then turn off the 220V power switch.

3, the company's commercial stove igniter series products, there are a variety of models for customers to choose, can also be customized according to customer requirements.

Fourth, high frequency high energy igniter installation precautions

1. The installer must have an electrician installation qualification.

2. 2. The rated input voltage of this igniter is 220V 50HZ. A qualified leakage circuit breaker must be installed at the front end of the power supply. The metal casing of the cooker must be protected by a grounding wire. It is strictly forbidden to connect the metal casing with a neutral wire!

3. The control switch on the panel should use a bipolar power switch of not less than 5A/250V, and the igniter power cord is connected to the power switch.

4. 4. The igniter can be fixed or suspended in the lower space of the cooker, and high temperature radiation baking should be avoided.

5, 5. High-voltage line is connected to the ignition needle. It is recommended to use dual-ignition ignition mode. The discharge spacing of the ignition needle is 3-5mm. Try not to use the single-discharge method. If only one high-voltage line is connected to the ignition needle, the other high-voltage line must be reliably connected. On the metal body of the burner, it can not be easily connected to the metal casing of the cooker, which will bring many difficult problems!

6. 6. The length of the high-voltage line is “long enough and shortest”. It is better to separate the two lines by more than 3 cm, and keep a certain degree of drooping arc to facilitate the oil drop. The high-voltage line can not be extended continuously. The wiring is not allowed to be close to the iron frame and iron plate of the stove. Do not add all kinds of casings. Never use the two high-voltage wires to twist together to avoid high-frequency high-voltage leakage!

7. Regularly clean up debris and do not rinse with water.

Five, the main product type of commercial stove igniter

The commercial stove igniter series products produced by our company are divided into powerful igniter, super igniter and high-energy igniter according to the ignition intensity. There are two kinds of delay ignition and continuous ignition according to the ignition mode. Electric start, jog button start and switch start, as well as output control fan start, so the following series of products have been produced, customers can purchase according to needs, or customize products according to customer requirements.

1; Strong ignition: This type of igniter is suitable for igniting flammable gas or vaporized alcohol-based fuel, and can also ignite high-purity liquid alcohol-based fuel.

2; super ignition: This type of igniter can ignite flammable gas and alcohol-based fuel, and the ignition needle can be ignited with a little water. It is especially suitable for point-based alcohol-based fuels, which contain different proportions of water in alcohol-based fuels.

3; high-energy ignition: This type of igniter has the strongest ignition capacity. The spark is like a flame. It can ignite some difficult fuels. It is also suitable for large-scale cooking stoves with fans. Because of the fan, the ignition sparks are scattered. Increasing the ignition area makes it easier to catch fire. Customers can choose according to their needs.

The commercial stove igniter produced by our company mainly has the following functions:

1, continuous ignition; ignition after powering until the power is turned off,

2, delay ignition; ignition after ignition for a certain time will automatically stop ignition, a certain time is generally 10-12 seconds, can also be set according to customer needs. If some customers require a delay ignition time of 20 seconds. The advantage of using such an igniter is that the life of the igniter is greatly extended.

3. The low-voltage jog button switch is activated; the igniter has a set of low-voltage switch start leads connected to the low-pressure push button switch to realize the low-voltage start igniter. This ignition mode is safer, not afraid of leakage and electric shock, and the low-voltage switch starts a little moving and button Self-locking, this is based on the user's habits.

4, synchronous control of the fan; igniter has a set of 220V voltage output leads, can be used to control the fan or electromagnetic pump.

The above functions can be selected according to their own needs. If there are other functions to be implemented, they can be customized.

The main products of the igniter produced by the company are as follows. 1, DQ7: 220V continuous powerful ignition. 2, DQ2: 220V with extended powerful ignition. 3, DQ6: 220V continuous super ignition. 4, DQ3: 220V with time delay super ignition.

5, DQ5: 220V with time delay super ignition, low pressure button start.

6, DQ8: 220V with time delay super ignition, low pressure button start, synchronous control fan or electromagnetic pump. 7, DY3: 220V continuous high-energy ignition. 8, DY1: 220V with delayed high-energy ignition.

9, DY2: 220V with delayed high-energy ignition, low-voltage button to start.

10, DY6: 220V with delayed high-energy ignition, low-pressure button start, synchronous control of the fan or electromagnetic pump.